Software release, 03/30/2017

Post Reply
JuKu
Site Admin
Posts: 1110
Joined: Thu Feb 14, 2013 3:06 pm
Location: Tampere, Finland
Contact:

Software release, 03/30/2017

Post by JuKu »

Build date 3/30/2017

Please go to http://www.liteplacer.com/downloads for latest release.

New Features, significant changes

* Comma is internally converted to dot in input fields
* Added adjustable hysteresis to Z probing

Bug Fixes

* Increased default for "Allow Nozzle to below PCB" to 3mm
* Fixed an issue when number of nozzles and number of table rows could get out of sync
* Default number of nozzles is now six

----

Some explanations:

Comma is internally converted to dot in input fields: Internally and in the UI, the software uses US notation, with dot as a decimal separator. If an European user put comma in a number, it was accepted but ignored. Not good, if you put in 1,9 as a placement depth (for example), you got 19mm

Added adjustable hysteresis to Z probing: It is nozzle height setup box. The switches I use have built-in hysteresis. It seems to be production patch dependent, and if too small, leads to problems with probing. The default is zero, and if your system doesn't have issues, leave it that way. If you change it, recalibrate the nozzle height and reset z values on tapes.