Search found 4 matches

by fmartinho
Thu Aug 08, 2019 5:45 pm
Forum: Using the LitePlacer
Topic: Misaligned component placement
Replies: 4
Views: 9649

Misaligned component placement

I am currently experiencing two issues: The cam and the nozzle are not 100% aligned however I did the alignment with the test pcb. How can I improve this calibration? Another mistake is when I pickup this, the nozzle goes down activates the switch, and when it goes up the swtich deactivates and the ...
by fmartinho
Tue Jul 30, 2019 12:10 pm
Forum: Using the LitePlacer
Topic: (Solved)Needle height calibration don't stop
Replies: 4
Views: 5329

Re: Needle height calibration don't stop

Hello JuKu,
thank you for your time, and thank you for helping me, that's what I was missing.
Problem solved
by fmartinho
Fri Jul 26, 2019 8:08 am
Forum: Using the LitePlacer
Topic: (Solved)Needle height calibration don't stop
Replies: 4
Views: 5329

Re: Needle height calibration don't stop

Hell,
The boxes have the checks, however when I start nozzle height calibration they are automatically unchecked.
I can make a video, to show ...
If you don't understand my mistake.
by fmartinho
Thu Jul 25, 2019 5:09 pm
Forum: Using the LitePlacer
Topic: (Solved)Needle height calibration don't stop
Replies: 4
Views: 5329

(Solved)Needle height calibration don't stop

When the cousin starts calibration, a box switch (Max; Min and Homing) is deactivated, which causes the needle test not to stop, ie it does not stop and always goes down and I have to press the reset button or turn off the machine.
Can you help me please?