Search found 2 matches
- Sun May 24, 2020 7:01 pm
- Forum: Using the LitePlacer
- Topic: Liteplacer dos not work at all
- Replies: 5
- Views: 12246
Re: Liteplacer dos not work at all
Hey, Mechanically everyting is fine. After tensioning all belts to correct levels, distance per revolution is exactly 40mm. Now cameras and optical corrections. Cameras are well calibrated, pixels per mm are correct. Camera to nozzle offset is correct. I used plasticine to measure offset precisly - ...
- Tue May 19, 2020 6:10 pm
- Forum: Using the LitePlacer
- Topic: Liteplacer dos not work at all
- Replies: 5
- Views: 12246
Liteplacer dos not work at all
Hey. I have tried to get liteplacer work but no results so far. Machine accuracy is like one millimeter... when camera corrections is used. Steps I have done: * measured steps per mm very acurately using dial gauge with 0.01mm scale * measured pixels per mm * measured and corrected offset between do...