Timeout for Home XYZ

Post Reply
mawa
Posts: 139
Joined: Wed Jun 10, 2015 1:23 pm
Location: Near Hamburg, Germany

Timeout for Home XYZ

Post by mawa »

I got my LitePlace to work and the mechanic is running smooth and accurate. :D :D

I currently use the original Juha Software with the default homing acc and speed values (2000/2000 for X & Y 500/1000 for Z).

When I home the device from let's say the center of the work area the HomeXYZ works fine.

But I chose to set my park position in the upper right at MaxX/MaxY. When I Home XYZ from there I get a Timeout on Command {"gc":"G28.2 X0"} at the end of the X home and the mechanical step failed message.

I think that the 8000 timeout value is too short for that long run, or am I look at the wrong place?

Does this timeout also occur on other machines?
best regards
Manfred
mrandt
Posts: 407
Joined: Mon Apr 27, 2015 10:56 am
Location: Stuttgart, Germany

Re: Timeout for Home XYZ

Post by mrandt »

Hi Manfred,

same problem here - see issue #4:
https://github.com/jkuusama/LitePlacer-ver2/issues/4

Regards
Malte