Odd behavior on manually enabling vac pump

Post Reply
yaddatrance
Posts: 9
Joined: Sat Jun 17, 2017 8:22 am

Odd behavior on manually enabling vac pump

Post by yaddatrance »

When I click to turn on the vac pump manually, the x axis moves left a few mm then back. Is this expected?
JuKu
Site Admin
Posts: 1114
Joined: Thu Feb 14, 2013 3:06 pm
Location: Tampere, Finland
Contact:

Re: Odd behavior on manually enabling vac pump

Post by JuKu »

Yes. This is a limitation of the TinyG firmware; the command to turn on the pump needs a move before it is executed.
yaddatrance
Posts: 9
Joined: Sat Jun 17, 2017 8:22 am

Re: Odd behavior on manually enabling vac pump

Post by yaddatrance »

Great thanks