Post by ameli »

I was just wondering what the nominal values for the back-off and placement depth should be for the new nozzles in the upgrade kit.

The auto height calibration routine yielded a back-off value of 0.50. I tried adjusting the z-limit low switch to get the back-off greater than 1mm (as the documentation recommends), but I was unsuccessful. Do I need to play with the upper springs as well, with this new setup?

So my question is if the recommended backoff of 2mm is still valid for the CP40 nozzles?

I currently have a 0.50 backoff and placement depth of 0.25. I can't seem to place loose SOIC-8 parts without getting the z-limit switch to error out each time it tries to release onto the PCB.

Help please!
JuKu
Site Admin
Posts: 1114
Joined: Thu Feb 14, 2013 3:06 pm
Location: Tampere, Finland
Contact:

Re: Calibrate Needle Height with new CP40 nozzles

Post by JuKu »

> I tried adjusting the z-limit low switch to get the back-off greater than 1mm (as the documentation recommends), but I was unsuccessful.

Why? This indicates that the tube up/(done movement is restricted somehow, maybe too tight rotation belt or the bearings need alignment.